How to calculate the construction formwork quantities in a project based on design drawing?

Apr 28, 2022 Leave a message


1. Generally, the height of the formwork of columns, beams, slabs and walls shall be within 3.6m, and if the height exceeds 3.6m, the amount of supporting works shall be increased according to the excess part.


2. Holes with a single hole area of 0.3 square meters or less shall not be deducted, and the formwork of the side wall of the hole shall not be increased; when the area of a single hole is beyond 0.3 square meters, it shall be deducted, and the formwork area of the side wall of the hole shall be incorporated into the wall and plate formwork works calculated within the quantity.


3. The frame is calculated according to the relevant regulations of beams, slabs, columns and walls, and the wall columns are attached and included in the calculation of the amount of work in the wall. The area of the formwork is not calculated for the overlapping parts of the connection between the column and the beam, the column and the wall, and the beam and the beam, as well as the beam head and the plate head part extending into the wall. For the exposed surface of the structural column, the area of the formwork shall be calculated according to the exposed part. The formwork area is not calculated for the contact surface of the structural column and the wall. The cast-in-place reinforced concrete cantilever panels (awnings, balconies) are calculated according to the horizontal projected area of the overhanging part. The corbel beam and plate edge formwork out of the wall shall not be calculated separately.


4. For cast-in-place reinforced concrete stairs, it is calculated based on the horizontal projected area of the exposed surface size, without deducting the area occupied by the stairwell less than 500mm. Side formwork such as steps, treads, platform beams, etc. of stairs shall not be calculated separately. Concrete steps do not include ladder belts, and are calculated according to the horizontal area of the step size, and the formwork area is not calculated separately on both sides of the step end.


5. The small tank is calculated according to the peripheral volume of the component, and the templates inside, outside and at the bottom of the tank are not calculated separately.